Emergency plan rules in Georgia
2 license types researched, regulated by Georgia Department of Community Health — Healthcare Facility Regulation. Every requirement below carries the rule that imposes it.
Assisted living / residential care
Licensed in Georgia as Assisted Living Community (ALC), by Georgia Department of Community Health — Healthcare Facility Regulation.
Ga. Comp. R. & Regs. Ch. 111-8-16 (Disaster Preparedness Plans): R. 111-8-16-.03 (plan, rehearsals, review, coordination), -.04 (plan elements), -.05 (long-term care facilities), -.06 (records), -.08 (24-hour notice); Ch. 111-8-63 (Assisted Living Communities): R. 111-8-63-.09 (staff training), -.11(9) (fire safety); fire code adopted at R. 120-3-3-.04
Fire drill frequency is not verified. The Assisted Living Community rules set no routine fire drill frequency; they require compliance with the Safety Fire Commissioner's fire safety rules, and the Department may require an immediate fire safety drill when it doubts residents can be evacuated in time.
R. 111-8-63-.11(9)(a) refers drill frequency to the Safety Fire Commissioner's rules. Open the drill provisions of IFC 2024 §405 (Table 405.2) as adopted by Ga. Comp. R. & Regs. R. 120-3-3-.04 (https://rules.sos.ga.gov/gac/120-3-3), which were not read, and confirm with the local fire marshal which occupancy classification applies to the community.
No duty to file or submit the plan for approval was found in Ch. 111-8-16. The community keeps the plan, its changes, rehearsal records and records of incidents that required plan implementation, and provides them to the Department on request. The annual coordination duties with the local emergency management agency are listed separately.
This is a finding, not a gap: Georgia has no filing duty here, so the plan is kept on file rather than submitted anywhere.
Ch. 111-8-16 states no retention period. The plan and its changes, rehearsal records and records of incidents that required plan implementation must be kept and provided to the Department on request.
Emergency egress or escape routes, and whether evacuation is to be complete or — where approved — by selected floors or areas only; procedures for employees who remain to operate critical equipment before evacuating; procedures for assisted rescue of people unable to use the general means of egress unassisted; accounting for employees and occupants after evacuation; identification and assignment of personnel responsible for rescue or emergency medical aid; and the preferred and alternative means both of notifying occupants and of reporting to the fire department.
International Fire Code 2024 §404, as adopted by Ga. Comp. R. & Regs. R. 120-3-3-.04 — not yet confirmed against primary textWhen an emergency dictates implementation of the plan and results in injury or loss of life, the Department must be notified within 24 hours. This is a reportable-event clock that starts during the response, and the plan should name who owns it.
Ga. Comp. R. & Regs. R. 111-8-16-.08The community must have a written Disaster Preparedness Plan developed by its governing body. The plan must identify and assess residents' unique needs; cover at least fire, explosion, interruption of each utility, loss of air conditioning or heat, and severe-weather damage to the building; and address staff responsibilities, resident care, notice to attending physicians, transportation and hospitalization, availability of records, alternate living arrangements, emergency energy sources and written agreements with outside agencies.
Ga. Comp. R. & Regs. R. 111-8-16-.03(1), -.04The plan must be rehearsed at least twice in each calendar year, and the facility must review it at least annually and make appropriate updates. Rehearsals should not require the actual movement of non-ambulatory residents.
Ga. Comp. R. & Regs. R. 111-8-16-.03(1), -.04(5)The facility must open and maintain an account on the Department of Public Health's web-based emergency operations center, take part at least annually in regional healthcare coalition communication drills or meetings, and keep evidence of contact at least annually with the local emergency management agency coordinator.
Ga. Comp. R. & Regs. R. 111-8-16-.03(3)(a)–(c)As a long-term care facility, the community must have a pandemic plan for influenza and other infectious diseases that conforms to CDC standards, keep a minimum seven-day supply of protective masks, surgical gowns, eye protection and gloves, and update its infection-control policies annually.
Ga. Comp. R. & Regs. R. 111-8-16-.04(7), -.05Residents and their representatives must be told of a confirmed COVID-19 or airborne-disease case in the facility by 5:00 P.M. the next calendar day.
Ga. Comp. R. & Regs. R. 111-8-16-.05Emergency preparedness is a required orientation topic for staff within the first 60 days of employment.
Ga. Comp. R. & Regs. R. 111-8-63-.09(2)(d)Staff of assisted living communities must complete a minimum of 3 hours of initial fire-safety training within 90 days of licensure. The certification expires 3 years after it is issued.
Ga. Comp. R. & Regs. R. 120-3-3-.04 (IFC §403.1.1 as modified)If residents who need assisted self-preservation may not be evacuable to a designated point of safety in time, given staffing patterns, the Department may require the community to conduct an immediate fire safety drill or refer the matter to the State Fire Commissioner.
Ga. Comp. R. & Regs. R. 111-8-63-.11(9)(d)- Georgia's numbering is easy to reverse: 111-8-62 is PERSONAL CARE HOMES and 111-8-63 is ASSISTED LIVING COMMUNITIES. The separate disaster-preparedness chapter, 111-8-16, applies to facilities licensed under O.C.G.A. Title 31, Chapter 7, Article 1, except those R. 111-8-16-.02 exempts: family personal care homes, home health agencies, freestanding emergency care centers, specimen collection centers, federal and public-health facilities, and facilities other than nursing homes that are CMS-certified or accredited by a CMS-approved accrediting organization.
- drills — R. 111-8-63-.11(9)(a) refers drill frequency to the Safety Fire Commissioner's rules. Open the drill provisions of IFC 2024 §405 (Table 405.2) as adopted by Ga. Comp. R. & Regs. R. 120-3-3-.04 (https://rules.sos.ga.gov/gac/120-3-3), which were not read, and confirm with the local fire marshal which occupancy classification applies to the community.
- mandate[0] — This list is not in R. 111-8-63-.14 or -.13. It matches the model International Fire Code §404 fire evacuation plan contents. Open IFC 2024 §404 as adopted by R. 120-3-3-.04 (https://rules.sos.ga.gov/gac/120-3-3), which was not read, and confirm with the local fire marshal that §404 applies to the community's occupancy.
Reviewed 2026-09-28
Group home / residential care home
Licensed in Georgia as Personal Care Home (PCH), by Georgia Department of Community Health — Healthcare Facility Regulation.
Ga. Comp. R. & Regs. Ch. 111-8-62 (Personal Care Homes): R. 111-8-62-.07(3)(k) (emergency policies), -.09(2) (staff training), -.13 (safety); for homes other than family personal care homes, Ch. 111-8-16 (Disaster Preparedness Plans): R. 111-8-16-.02, -.03, -.04, -.05, -.06, -.08
Fire drill frequency is not verified. The Personal Care Home rules require the home's policies to address emergency preparedness, drills and evacuation, but set no drill frequency; fire safety follows the Safety Fire Commissioner's rules.
R. 111-8-62-.07(3)(k) and -.13(1) set no drill frequency. Open the drill provisions of IFC 2024 §405 as adopted by Ga. Comp. R. & Regs. R. 120-3-3-.04 (https://rules.sos.ga.gov/gac/120-3-3), which were not read, and confirm with the local fire marshal which occupancy classification applies to the home.
No duty to file or submit the plan for approval was found in Ch. 111-8-62 or Ch. 111-8-16. A home covered by Ch. 111-8-16 keeps its plan and rehearsal and incident records and provides them to the Department on request.
This is a finding, not a gap: Georgia has no filing duty here, so the plan is kept on file rather than submitted anywhere.
Ch. 111-8-16 states no retention period. A home covered by it keeps the plan and its changes, rehearsal records and records of incidents that required plan implementation, and provides them to the Department on request.
At least one charged 5 lb multipurpose ABC fire extinguisher on each occupied floor and in the basement, checked annually. Georgia specifies the size and the placement, not just the presence.
Ga. Comp. R. & Regs. R. 111-8-62-.13(2)(f)The home must have an established procedure and mechanism for alerting and caring for residents in case of emergencies and evacuating them to safety. A plan showing escape routes must be posted on each floor.
Ga. Comp. R. & Regs. R. 111-8-62-.13(2)(b), (16)(b)A personal care home other than a family personal care home must have a written Disaster Preparedness Plan with the elements in R. 111-8-16-.04, rehearse it at least twice each calendar year, and review it at least annually. It must also keep an account on the Department of Public Health's web-based emergency operations center, take part at least annually in healthcare coalition communication drills or meetings, and keep evidence of contact at least annually with the local emergency management agency coordinator.
Ga. Comp. R. & Regs. R. 111-8-16-.02, -.03, -.04In a home covered by Ch. 111-8-16, when an emergency dictates implementation of the plan and results in injury or loss of life, the Department must be notified within 24 hours.
Ga. Comp. R. & Regs. R. 111-8-16-.08A personal care home with 25 or more beds is a long-term care facility under Ch. 111-8-16. It must have a pandemic plan that conforms to CDC standards, keep a minimum seven-day supply of protective masks, surgical gowns, eye protection and gloves, and tell residents and their representatives of a confirmed COVID-19 or airborne-disease case by 5:00 P.M. the next calendar day.
Ga. Comp. R. & Regs. R. 111-8-16-.01, -.05Staff must be trained in emergency evacuation procedures within the first 60 days of employment.
Ga. Comp. R. & Regs. R. 111-8-62-.09(2)Staff of personal care homes must complete a minimum of 3 hours of initial fire-safety training within 90 days of licensure. The certification expires 3 years after it is issued.
Ga. Comp. R. & Regs. R. 120-3-3-.04 (IFC §403.1.1 as modified)- Family personal care homes are exempt from the disaster-preparedness chapter, Ch. 111-8-16 (R. 111-8-16-.02). The Ch. 111-8-16 duties in this entry apply to other personal care homes.
- drills — R. 111-8-62-.07(3)(k) and -.13(1) set no drill frequency. Open the drill provisions of IFC 2024 §405 as adopted by Ga. Comp. R. & Regs. R. 120-3-3-.04 (https://rules.sos.ga.gov/gac/120-3-3), which were not read, and confirm with the local fire marshal which occupancy classification applies to the home.
Reviewed 2026-09-28
Build a Georgia emergency plan →
Everything else we’ve researched about Georgia
Same state, the problems either side of this one. Each carries its own statute and the date we last checked it.
- Georgia deposit return law & letterThe landlord's deadline to return a deposit, and the itemized letter.
- Georgia deposit demand letterFor the tenant: whether the landlord is late, and by how many days.
- Georgia deposit deduction rulesWhat may fairly come out of a deposit, prorated by useful life.
- Georgia move-in condition reportThe walkthrough record that decides deposit arguments later.
What this page is
The requirements Georgia places on a facility emergency preparedness plan, taken from the state’s own rules rather than a national template. Where we have confirmed something against primary text it is stated plainly; where we have not, it says so and names what to check. Nothing here is inferred from what other states do.
The part that is the same everywhere
The federal layer does not vary by state, and it is narrower than it is usually described. OSHA 29 CFR §1910.38 does not bind every employer on its own — by its applicability paragraph it governs an emergency action plan whenever another OSHA standard requires the employer to have one, and it then settles what that plan must contain. The CMS emergency preparedness rule applies by certified provider type rather than by building. That layer, plus the exit-route, alarm and first-aid rules and the fire code’s plan structure, is covered in the main crash course rather than repeated on all fifty state pages.
Write the plan
The Emergency Plan Builder produces the document itself. It reads the same research as this page, but it does not yet carry every requirement here into the plan it writes, so check the plan against this page before you rely on it for Georgia. The Compliance Calendar puts the drills and inspections on dates.