Example · not a real building
A sample Oregon assisted living binder
This is what an Oregon assisted living facility's binder looks like when its drills, checks and repairs are kept in CompliMaint. Juniper House is fictional: every name, date, reading and work order below is made up, and the dates move with today's.
Example. The Oregon rules printed here are real, each cited with the date we checked it; the building and its records are not. CompliMaint doesn't decide whether a building is compliant; the licensing agency does.
Compliance binder · example
Juniper House
- Building
- An Oregon assisted living facility, 72 beds (example; no license number)
- Scope
- Every category on the building's list
- Period
- Nov 24, 2025 – Nov 24, 2026
- Printed
- Nov 24, 2026 by the maintenance director
Contents: At a glance · Problems and late items · Corrective work still open · Fire drills · Staff fire and life safety instruction · Emergency preparedness plan · Fire extinguishers · Hot water
At a glance
Every item on this building's list for Nov 24, 2025 – Nov 24, 2026. 39 due · 38 on time · 1 late · 0 missed · 1 open problem · nothing overdue.
| Item | How often | Due in period | On time | Late | Missed | Last done | Next due | Status |
|---|---|---|---|---|---|---|---|---|
| Fire drills | ||||||||
| Fire drill, unannounced — day, evening and night shifts in turn | Every other month | 6 | 5 | 1 | 0 | Oct 19, 2026 | Dec 31, 2026 | Done |
| Staff fire and life safety instruction | ||||||||
| Fire and life safety instruction to staff | Alternate months | 6 | 6 | 0 | 0 | Sep 22, 2026 | Nov 30, 2026 | Done |
| Emergency preparedness plan | ||||||||
| Drill of the emergency plan (one may be a tabletop) | Twice a year | 2 | 2 | 0 | 0 | Aug 21, 2026 | Mar 1, 2027 | Done |
| Plan reviewed or updated, kept on site | Every year | 1 | 1 | 0 | 0 | Dec 17, 2025 | Dec 31, 2026 | Done |
| Fire extinguishers | ||||||||
| Extinguishers on each floor, monthly look | Monthly | 12 | 12 | 0 | 0 | Oct 28, 2026 | Nov 30, 2026 | Done |
| Hot water | ||||||||
| Hot water in residents' units | Monthly | 12 | 12 | 0 | 0 | Oct 26, 2026 | Nov 30, 2026 | Open problem |
| All items | 39 | 38 | 1 | 0 | 1 open problem | |||
On time = done by its due date · Late = done after it · Missed = never done for that cycle · Open problem = a check failed and no fix is recorded yet.
Problems and late items
Every failed check, missed test and late completion in the period. Open first, then newest first.
| Found | What | Where | What was done | Status |
|---|---|---|---|---|
| Oct 26, 2026 | Hot water read 123 °F in Room 214, above Oregon's 110–120 °F range | Room 214 | Work order WO-2207 opened to adjust the mixing valve. | Open |
| Jul 3, 2026 | Fire drill done 3 days late (due Jun 30, 2026) | East wing | The next drill was put on the calendar two weeks earlier. | Closed |
Corrective work still open
| Work order | Item | Status |
|---|---|---|
| WO-2207 Adjust the mixing valve serving Room 214 | Hot water in residents' units | Open — plumber booked |
Category
Fire drills
Fire drill, unannounced — day, evening and night shifts in turn
Juniper House · every other month · rule: OAR 411-054-0090(1)(a), (d) — every other month, at different times of the day, evening and night shifts; the record shows the date and time, fire origin, route, problems, evacuation time, staff and occupants · checked Nov 22, 2026
| Due | Done | Result |
|---|---|---|
| Oct 31, 2026 | Oct 19, 2026 | On time |
| Aug 31, 2026 | Aug 19, 2026 | On time |
| Jun 30, 2026 | Jul 3, 2026 | Late |
| Apr 30, 2026 | Apr 18, 2026 | On time |
| Feb 28, 2026 | Feb 16, 2026 | On time |
| Dec 31, 2025 | Dec 19, 2025 | On time |
Category
Staff fire and life safety instruction
Fire and life safety instruction to staff
Juniper House · alternate months · rule: OAR 411-054-0090(1)(b) · checked Nov 22, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 22, 2026 | On time |
| Jul 31, 2026 | Jul 23, 2026 | On time |
| May 31, 2026 | May 23, 2026 | On time |
| Mar 31, 2026 | Mar 23, 2026 | On time |
| Jan 31, 2026 | Jan 23, 2026 | On time |
| Nov 30, 2025 | Nov 22, 2025 | On time |
Category
Emergency preparedness plan
Drill of the emergency plan (one may be a tabletop)
Juniper House · twice a year · rule: OAR 411-054-0093(4) — at least twice a year; it does not replace the fire drills · checked Nov 22, 2026
| Due | Done | Result |
|---|---|---|
| Aug 31, 2026 | Aug 21, 2026 | On time |
| Feb 28, 2026 | Feb 18, 2026 | On time |
Plan reviewed or updated, kept on site
Juniper House · every year · rule: OAR 411-054-0093(5) · checked Nov 22, 2026
| Due | Done | Result |
|---|---|---|
| Dec 31, 2025 | Dec 17, 2025 | On time |
Category
Fire extinguishers
Extinguishers on each floor, monthly look
Juniper House · monthly · rule: OAR 411-054-0090(3), (3)(a) — 2A:10B:C on each floor, maintained under the Oregon Fire Code and the maker's instructions; Oregon's licensing rule sets no interval of its own; the Oregon Fire Code it points to brings in NFPA 10's monthly inspection · checked Nov 22, 2026
| Due | Done | Result |
|---|---|---|
| Oct 31, 2026 | Oct 28, 2026 | On time |
| Sep 30, 2026 | Sep 27, 2026 | On time |
| Aug 31, 2026 | Aug 28, 2026 | On time |
| Jul 31, 2026 | Jul 28, 2026 | On time |
| Jun 30, 2026 | Jun 27, 2026 | On time |
| May 31, 2026 | May 28, 2026 | On time |
| Apr 30, 2026 | Apr 27, 2026 | On time |
| Mar 31, 2026 | Mar 28, 2026 | On time |
| Feb 28, 2026 | Feb 25, 2026 | On time |
| Jan 31, 2026 | Jan 28, 2026 | On time |
| Dec 31, 2025 | Dec 28, 2025 | On time |
| Nov 30, 2025 | Nov 27, 2025 | On time |
Category
Hot water
Hot water in residents' units
Juniper House · monthly · rule: OAR 411-054-0300(9)(a) — 110–120 °F, for a building licensed on or after Jan 15, 2015; the rule sets the range, how often to check is the building's choice · checked Nov 22, 2026
| Due | Done | Result | Reading |
|---|---|---|---|
| Oct 31, 2026 | Oct 26, 2026 | On time | 123 °F, Room 214 |
| Sep 30, 2026 | Sep 25, 2026 | On time | 116 °F |
| Aug 31, 2026 | Aug 26, 2026 | On time | 115 °F |
| Jul 31, 2026 | Jul 26, 2026 | On time | 114 °F |
| Jun 30, 2026 | Jun 25, 2026 | On time | 117 °F |
| May 31, 2026 | May 26, 2026 | On time | 116 °F |
| Apr 30, 2026 | Apr 25, 2026 | On time | 115 °F |
| Mar 31, 2026 | Mar 26, 2026 | On time | 114 °F |
| Feb 28, 2026 | Feb 23, 2026 | On time | 117 °F |
| Jan 31, 2026 | Jan 26, 2026 | On time | 116 °F |
| Dec 31, 2025 | Dec 26, 2025 | On time | 115 °F |
| Nov 30, 2025 | Nov 25, 2025 | On time | 114 °F |
Each rule line is Oregon's own, cited with the day it was read on the official text. Where Oregon's rule sets no interval of its own, the line says so, and says where the building's interval comes from. Oregon's assisted living rules set no generator or emergency power rule, so none is printed.
Keep your buildings' records this way
Your binder fills itself from what you record, and lists anything still missing.
Try it free — no cardSee it for Oregon assisted living
This page is an example. Juniper House is fictional.