For Oregon assisted living and residential care
Your Oregon community's drills, checks and repairs in one place.
Made for maintenance and executive directors at Oregon Assisted Living Facilities (ALF) and Residential Care Facilities (RCF). Add your building and CompliMaint lays out Oregon's fire drills, your emergency plan's drills and review, work orders, maintenance schedules and a binder for the building.
Try it free for your first year. Limited time. No card needed. Staff logins are included in your free first year. Invite each person on one screen and choose the buildings they cover. Nobody is charged without being told the price and agreeing to it first.
CompliMaint is new, early-access software. Print or export your records any time, and keep your own copy of anything you’re required to keep.
The Oregon rules it follows
From Oregon Administrative Rules chapter 411, division 54, the rules the Oregon Department of Human Services licenses an ALF or RCF under. Each one was read on the Oregon Secretary of State's official text, checked November 22, 2026.
Fire drills
Unannounced fire drills conducted and recorded every other month at different times of the day, evening, and night shifts, under the Oregon Fire Code. The fire alarm is activated during each drill unless the Fire Authority directs otherwise, and alternate exit routes are used.
OAR 411-054-0090(1)(a), (e), (h) · checked November 22, 2026
What every fire drill record must show
A written fire drill record documents each drill: the date and time of day; the location of the simulated fire origin; the escape route used; problems encountered and comments about residents who resisted or failed to take part; the evacuation time needed; the staff members on duty and taking part; and the number of occupants evacuated.
OAR 411-054-0090(1)(d) · checked November 22, 2026
Fire and life safety instruction to staff on alternate months
Fire and life safety instruction to staff must be provided on alternate months. The rule says alternate months; it does not say which.
OAR 411-054-0090(1)(b) · checked November 22, 2026
Residents instructed within 24 hours of admission, and every year
Each resident is instructed within 24 hours of admission and re-instructed at least annually in general safety procedures, evacuation methods, responsibilities during fire drills and designated meeting places. A written record of the training, its content and the residents attending, is kept. This does not apply to a resident whose mental capability does not allow for following the instruction.
OAR 411-054-0090(5)(a), (b) · checked November 22, 2026
Fire detection and protection equipment maintained; extinguishers on each floor
Fire detection and protection equipment, including visual signals with alarms for hearing-impaired residents, must be maintained in accordance with the Oregon Fire Code and the manufacturer's instructions. The facility provides and maintains one or more 2A:10B:C fire extinguishers on each floor. The rule sets no checking interval of its own; it points to the Oregon Fire Code and the manufacturer.
OAR 411-054-0090(3), (3)(a) · checked November 22, 2026
A written emergency preparedness plan, with three days' supplies
The facility prepares and maintains a written emergency preparedness plan under the Oregon Fire Code. It analyzes and responds to hazards including evacuation; fire, smoke, bomb threat and explosion; prolonged power failure, water and sewer loss; structural damage; hurricane, tornado, tsunami, volcanic eruption, flood and earthquake; chemical spill or leak; and pandemic. It addresses residents' access to medical records and to pharmaceuticals, supplies and equipment during and after an evacuation, and includes provisions and supplies to shelter in place for a minimum of three days without electricity, running water or replacement staff.
OAR 411-054-0093(1), (2) · checked November 22, 2026
A drill of the emergency plan at least twice a year
The facility conducts a drill of the emergency preparedness plan at least twice a year. One of them may be a walk-through of the duties or a tabletop discussion of a hypothetical event. These drills do not take the place of the required fire drills.
OAR 411-054-0093(4) · checked November 22, 2026
The emergency plan reviewed or updated every year, and kept on site
The facility reviews or updates the emergency preparedness plan annually, and the plan is available on-site for review upon request.
OAR 411-054-0093(5) · checked November 22, 2026
Hot water in residents' units between 110 °F and 120 °F
Hot water temperature in residents' units must be maintained within a range of 110–120 °F. This building rule reaches an ALF or RCF not licensed before January 15, 2015, or a major alteration after that date; for an older building the rule does not say. It sets the range, not how often to check it.
OAR 411-054-0300(9)(a) (ALF); OAR 411-054-0200(9)(a) (RCF) · checked November 22, 2026
Heat: 70 °F in the day, 60 °F during sleeping hours
Heating systems can maintain 70 °F in resident areas; required minimums are 70 °F during the day and 60 °F during sleeping hours. In extreme summer heat, fans are made available where there is no air conditioning. Like hot water, this reaches a building licensed on or after January 15, 2015, or a major alteration after that date.
OAR 411-054-0300(8)(a) (ALF); OAR 411-054-0200(8)(a) (RCF) · checked November 22, 2026
Where Oregon's rules are silent
- No generator or emergency power rule. Oregon's assisted living and residential care rules (OAR 411-054) don't require a generator or emergency power. Your emergency plan must cover a prolonged power failure and three days without electricity. If your building has a generator, its testing comes from the fire and building codes, not from these rules. CompliMaint keeps a generator log for it, without calling it an Oregon licensing rule.
- No checking interval for fire equipment. OAR 411-054-0090(3) says fire alarm and fire protection equipment is maintained under the Oregon Fire Code and the manufacturer's instructions. It sets no monthly or yearly interval of its own, so none is shown as Oregon's rule.
- Hot water and heat: newer buildings. The 110–120 °F hot water range and the 70 °F / 60 °F heat minimums are in the building rules for a facility licensed on or after January 15, 2015, or a major alteration after that date. For an older building, those rules don't say.
A binder for each building
Every drill, check and repair you record is filed to the building, with what's missing listed — the drill records showing what OAR 411-054-0090(1)(d) asks each one to show.
See a sample Oregon assisted living binder (example data from a fictional building).
What it doesn't do
- CompliMaint doesn't decide whether your facility is compliant — the Oregon Department of Human Services and your fire authority do.
- CompliMaint isn't HIPAA compliant, so please don't enter residents' health information.
- CompliMaint isn't affiliated with or approved by any state agency.
Start with your first building
Create your account; setup opens your first building on Oregon and assisted living.
Not in Oregon? See CompliMaint for assisted living & multi-site.