Example · not a real building
A sample Washington assisted living binder
This is what a Washington assisted living facility's binder looks like when its plan, checks and repairs are kept in CompliMaint. Larch House is fictional: every name, date, reading and work order below is made up, and the dates move with today's.
Example. The Washington rules printed here are real, each cited with the date we checked it; the building and its records are not. CompliMaint doesn't decide whether a building is compliant; the licensing agency does.
Compliance binder · example
Larch House
- Building
- A Washington assisted living facility, 64 beds (example; no license number)
- Scope
- Every category on the building's list
- Period
- Nov 24, 2025 – Nov 24, 2026
- Printed
- Nov 24, 2026 by the maintenance director
Contents: At a glance · Problems and late items · Corrective work still open · Emergency preparedness plan · Emergency lighting · Hot water
At a glance
Every item on this building's list for Nov 24, 2025 – Nov 24, 2026. 30 due · 29 on time · 1 late · 0 missed · 1 open problem · nothing overdue.
| Item | How often | Due in period | On time | Late | Missed | Last done | Next due | Status |
|---|---|---|---|---|---|---|---|---|
| Emergency preparedness plan | ||||||||
| Plan reviewed and updated | Every year | 1 | 1 | 0 | 0 | Jan 19, 2026 | Jan 31, 2027 | Done |
| Staff trained in the plan (yearly review; new hires on hire) | Every year | 1 | 1 | 0 | 0 | Feb 19, 2026 | Feb 28, 2027 | Done |
| Personal protective equipment counted | Each quarter | 4 | 4 | 0 | 0 | Sep 23, 2026 | Dec 31, 2026 | Done |
| Emergency lighting | ||||||||
| Emergency lights and flashlights, monthly look | Monthly | 12 | 11 | 1 | 0 | Oct 29, 2026 | Nov 30, 2026 | Done |
| Hot water | ||||||||
| Hot water at residents' sinks and bathing fixtures | Monthly | 12 | 12 | 0 | 0 | Oct 26, 2026 | Nov 30, 2026 | Open problem |
| All items | 30 | 29 | 1 | 0 | 1 open problem | |||
On time = done by its due date · Late = done after it · Missed = never done for that cycle · Open problem = a check failed and no fix is recorded yet.
Problems and late items
Every failed check, missed test and late completion in the period. Open first, then newest first.
| Found | What | Where | What was done | Status |
|---|---|---|---|---|
| Oct 26, 2026 | Hot water read 123 °F in the Room 108 bath, above Washington's 105–120 °F range | Room 108 | Work order WO-3114 opened to adjust the mixing valve. | Open |
| May 3, 2026 | Emergency lights look done 3 days late (due Apr 30, 2026) | Every floor | The next look was put on the calendar a week earlier. | Closed |
Corrective work still open
| Work order | Item | Status |
|---|---|---|
| WO-3114 Adjust the mixing valve serving the Room 108 bath | Hot water at residents' sinks and bathing fixtures | Open — plumber booked |
Category
Emergency preparedness plan
Plan reviewed and updated
Larch House · every year · rule: WAC 388-78A-2700(5)(c) — review the plan and procedures and update at least annually · checked Nov 23, 2026
| Due | Done | Result |
|---|---|---|
| Jan 31, 2026 | Jan 19, 2026 | On time |
Staff trained in the plan (yearly review; new hires on hire)
Larch House · every year · rule: WAC 388-78A-2700(5)(b) — all employees trained upon hire and reviewed annually thereafter · checked Nov 23, 2026
| Due | Done | Result |
|---|---|---|
| Feb 28, 2026 | Feb 19, 2026 | On time |
Personal protective equipment counted
Larch House · each quarter · rule: WAC 388-78A-2700(5)(a) — an adequate supply of gloves, gowns, surgical masks, eye protection and NIOSH-approved respirators; Washington's rule sets no interval, the quarterly count is the building's choice · checked Nov 23, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 23, 2026 | On time |
| Jun 30, 2026 | Jun 23, 2026 | On time |
| Mar 31, 2026 | Mar 24, 2026 | On time |
| Dec 31, 2025 | Dec 24, 2025 | On time |
Category
Emergency lighting
Emergency lights and flashlights, monthly look
Larch House · monthly · rule: WAC 388-78A-2700(1)(d) — emergency lighting or flashlights in all areas accessible to residents; Washington's licensing rule sets no testing interval of its own — the building's fire code and the maker's instructions govern the testing, and this example looks monthly · checked Nov 23, 2026
| Due | Done | Result |
|---|---|---|
| Oct 31, 2026 | Oct 29, 2026 | On time |
| Sep 30, 2026 | Sep 28, 2026 | On time |
| Aug 31, 2026 | Aug 29, 2026 | On time |
| Jul 31, 2026 | Jul 29, 2026 | On time |
| Jun 30, 2026 | Jun 28, 2026 | On time |
| May 31, 2026 | May 29, 2026 | On time |
| Apr 30, 2026 | May 3, 2026 | Late |
| Mar 31, 2026 | Mar 29, 2026 | On time |
| Feb 28, 2026 | Feb 26, 2026 | On time |
| Jan 31, 2026 | Jan 29, 2026 | On time |
| Dec 31, 2025 | Dec 29, 2025 | On time |
| Nov 30, 2025 | Nov 28, 2025 | On time |
Category
Hot water
Hot water at residents' sinks and bathing fixtures
Larch House · monthly · rule: WAC 388-78A-2950(6) — between 105 °F and 120 °F at all times; the rule sets the range, how often to check is the building's choice · checked Nov 23, 2026
| Due | Done | Result | Reading |
|---|---|---|---|
| Oct 31, 2026 | Oct 26, 2026 | On time | 123 °F, Room 108 bath |
| Sep 30, 2026 | Sep 25, 2026 | On time | 114 °F |
| Aug 31, 2026 | Aug 26, 2026 | On time | 113 °F |
| Jul 31, 2026 | Jul 26, 2026 | On time | 112 °F |
| Jun 30, 2026 | Jun 25, 2026 | On time | 115 °F |
| May 31, 2026 | May 26, 2026 | On time | 114 °F |
| Apr 30, 2026 | Apr 25, 2026 | On time | 113 °F |
| Mar 31, 2026 | Mar 26, 2026 | On time | 112 °F |
| Feb 28, 2026 | Feb 23, 2026 | On time | 115 °F |
| Jan 31, 2026 | Jan 26, 2026 | On time | 114 °F |
| Dec 31, 2025 | Dec 26, 2025 | On time | 113 °F |
| Nov 30, 2025 | Nov 25, 2025 | On time | 112 °F |
Each rule line is Washington's own, cited with the day it was read on the official text. Where Washington's rule sets no interval of its own, the line says so, and says where the building's interval comes from. Washington's assisted living rules set no generator or emergency power rule, so none is printed. Washington's assisted living rules set no fire drill schedule of their own: an existing facility's drills come from the fire code it must meet (WAC 388-78A-2851(3)), so no drill line is printed as a Washington rule. A real building's binder lists the drills it recorded.
Keep your buildings' records this way
Your binder fills itself from what you record, and lists anything still missing.
Try it free — no cardSee it for Washington assisted living
This page is an example. Larch House is fictional.