Example · not a real building
A sample California assisted living binder
This is what a California assisted living community's (RCFE's) binder looks like when its drills, plan, checks and repairs are kept in CompliMaint. Manzanita House is fictional: every name, date, reading and work order below is made up, and the dates move with today's.
Example. The California rules printed here are real, each cited with the date we checked it; the building and its records are not. CompliMaint doesn't decide whether a building is compliant; the licensing agency does.
Compliance binder · example
Manzanita House
- Building
- A California assisted living facility, 96 beds (example; no license number)
- Scope
- Every category on the building's list
- Period
- Nov 24, 2025 – Nov 24, 2026
- Printed
- Nov 24, 2026 by the maintenance director
Contents: At a glance · Problems and late items · Corrective work still open · Fire and emergency drills · Emergency and disaster plan · Carbon monoxide detectors · Hot water · Refrigerators and freezers
At a glance
Every item on this building's list for Nov 24, 2025 – Nov 24, 2026. 42 due · 41 on time · 1 late · 0 missed · 1 open problem · nothing overdue.
| Item | How often | Due in period | On time | Late | Missed | Last done | Next due | Status |
|---|---|---|---|---|---|---|---|---|
| Fire and emergency drills | ||||||||
| Drill, day shift | Each quarter | 4 | 4 | 0 | 0 | Sep 10, 2026 | Dec 31, 2026 | Done |
| Drill, evening shift | Each quarter | 4 | 4 | 0 | 0 | Sep 15, 2026 | Dec 31, 2026 | Done |
| Drill, night shift | Each quarter | 4 | 3 | 1 | 0 | Sep 20, 2026 | Dec 31, 2026 | Done |
| Emergency and disaster plan | ||||||||
| Plan reviewed, signed and dated | Every year | 1 | 1 | 0 | 0 | Jan 19, 2026 | Jan 31, 2027 | Done |
| Staff trained on the plan (yearly; new hires on hire) | Every year | 1 | 1 | 0 | 0 | Mar 22, 2026 | Mar 31, 2027 | Done |
| Carbon monoxide detectors | ||||||||
| Carbon monoxide detectors tested | Each quarter | 4 | 4 | 0 | 0 | Sep 23, 2026 | Dec 31, 2026 | Done |
| Hot water | ||||||||
| Hot water at residents' faucets | Monthly | 12 | 12 | 0 | 0 | Oct 26, 2026 | Nov 30, 2026 | Open problem |
| Refrigerators and freezers | ||||||||
| Kitchen refrigerators and freezers | Monthly | 12 | 12 | 0 | 0 | Oct 27, 2026 | Nov 30, 2026 | Done |
| All items | 42 | 41 | 1 | 0 | 1 open problem | |||
On time = done by its due date · Late = done after it · Missed = never done for that cycle · Open problem = a check failed and no fix is recorded yet.
Problems and late items
Every failed check, missed test and late completion in the period. Open first, then newest first.
| Found | What | Where | What was done | Status |
|---|---|---|---|---|
| Oct 26, 2026 | Hot water read 124 °F in the Room 112 bath, above California's 105–120 °F range | Room 112 | Work order WO-4127 opened to adjust the mixing valve. | Open |
| Jul 3, 2026 | Night-shift drill done 3 days late (due Jun 30, 2026) | North wing | The next night drill was put on the calendar three weeks earlier. | Closed |
Corrective work still open
| Work order | Item | Status |
|---|---|---|
| WO-4127 Adjust the mixing valve serving the Room 112 bath | Hot water at residents' faucets | Open — plumber booked |
Category
Fire and emergency drills
Drill, day shift
Manzanita House · each quarter · rule: Cal. Health & Safety Code §1569.695(c) — a drill at least quarterly for each shift; the type of emergency varies from quarter to quarter; the record names the date, the type of emergency and the staff who took part · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 10, 2026 | On time |
| Jun 30, 2026 | Jun 10, 2026 | On time |
| Mar 31, 2026 | Mar 11, 2026 | On time |
| Dec 31, 2025 | Dec 11, 2025 | On time |
Drill, evening shift
Manzanita House · each quarter · rule: Cal. Health & Safety Code §1569.695(c) — a drill at least quarterly for each shift; the type of emergency varies from quarter to quarter; the record names the date, the type of emergency and the staff who took part · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 15, 2026 | On time |
| Jun 30, 2026 | Jun 15, 2026 | On time |
| Mar 31, 2026 | Mar 16, 2026 | On time |
| Dec 31, 2025 | Dec 16, 2025 | On time |
Drill, night shift
Manzanita House · each quarter · rule: Cal. Health & Safety Code §1569.695(c) — a drill at least quarterly for each shift; the type of emergency varies from quarter to quarter; the record names the date, the type of emergency and the staff who took part · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 20, 2026 | On time |
| Jun 30, 2026 | Jul 3, 2026 | Late |
| Mar 31, 2026 | Mar 21, 2026 | On time |
| Dec 31, 2025 | Dec 21, 2025 | On time |
Category
Emergency and disaster plan
Plan reviewed, signed and dated
Manzanita House · every year · rule: Cal. Health & Safety Code §1569.695(d) — reviewed annually and updated as necessary; the licensee or administrator signs and dates it · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Jan 31, 2026 | Jan 19, 2026 | On time |
Staff trained on the plan (yearly; new hires on hire)
Manzanita House · every year · rule: Cal. Health & Safety Code §1569.695(b) — each staff member upon hire and annually thereafter · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Mar 31, 2026 | Mar 22, 2026 | On time |
Category
Carbon monoxide detectors
Carbon monoxide detectors tested
Manzanita House · each quarter · rule: Cal. Health & Safety Code §1569.311 — one or more detectors meeting the State Fire Marshal's standards; the law sets no testing interval, the quarterly test is the building's choice (each maker's instructions govern) · checked Nov 13, 2026
| Due | Done | Result |
|---|---|---|
| Sep 30, 2026 | Sep 23, 2026 | On time |
| Jun 30, 2026 | Jun 23, 2026 | On time |
| Mar 31, 2026 | Mar 24, 2026 | On time |
| Dec 31, 2025 | Dec 24, 2025 | On time |
Category
Hot water
Hot water at residents' faucets
Manzanita House · monthly · rule: 22 CCR §87303(e)(2), (e)(3) — not less than 105 °F and not more than 120 °F; a tap at 125 °F or more marked with a warning sign; the rule sets the range, how often to check is the building's choice · checked Nov 13, 2026
| Due | Done | Result | Reading |
|---|---|---|---|
| Oct 31, 2026 | Oct 26, 2026 | On time | 124 °F, Room 112 bath |
| Sep 30, 2026 | Sep 25, 2026 | On time | 112 °F |
| Aug 31, 2026 | Aug 26, 2026 | On time | 111 °F |
| Jul 31, 2026 | Jul 26, 2026 | On time | 110 °F |
| Jun 30, 2026 | Jun 25, 2026 | On time | 113 °F |
| May 31, 2026 | May 26, 2026 | On time | 112 °F |
| Apr 30, 2026 | Apr 25, 2026 | On time | 111 °F |
| Mar 31, 2026 | Mar 26, 2026 | On time | 110 °F |
| Feb 28, 2026 | Feb 23, 2026 | On time | 113 °F |
| Jan 31, 2026 | Jan 26, 2026 | On time | 112 °F |
| Dec 31, 2025 | Dec 26, 2025 | On time | 111 °F |
| Nov 30, 2025 | Nov 25, 2025 | On time | 110 °F |
Category
Refrigerators and freezers
Kitchen refrigerators and freezers
Manzanita House · monthly · rule: 22 CCR §87555(b)(21) — refrigerators at a maximum of 40 °F, freezers at 0 °F; the rule sets the temperatures, how often to check is the building's choice · checked Nov 13, 2026
| Due | Done | Result | Reading |
|---|---|---|---|
| Oct 31, 2026 | Oct 27, 2026 | On time | 38 °F / -1 °F |
| Sep 30, 2026 | Sep 26, 2026 | On time | 37 °F / -2 °F |
| Aug 31, 2026 | Aug 27, 2026 | On time | 36 °F / -1 °F |
| Jul 31, 2026 | Jul 27, 2026 | On time | 38 °F / -2 °F |
| Jun 30, 2026 | Jun 26, 2026 | On time | 37 °F / -1 °F |
| May 31, 2026 | May 27, 2026 | On time | 36 °F / -2 °F |
| Apr 30, 2026 | Apr 26, 2026 | On time | 38 °F / -1 °F |
| Mar 31, 2026 | Mar 27, 2026 | On time | 37 °F / -2 °F |
| Feb 28, 2026 | Feb 24, 2026 | On time | 36 °F / -1 °F |
| Jan 31, 2026 | Jan 27, 2026 | On time | 38 °F / -2 °F |
| Dec 31, 2025 | Dec 27, 2025 | On time | 37 °F / -1 °F |
| Nov 30, 2025 | Nov 26, 2025 | On time | 36 °F / -2 °F |
Each rule line is California's own, cited with the day it was read on the official text. Where California's rule sets no interval of its own, the line says so, and says where the building's interval comes from. None of the California sections printed here sets a generator or emergency power rule, and CompliMaint hasn't read one for RCFEs, so none is printed as California's. The same rules hold an RCFE of six beds or two hundred: none of these sections turns on the number of residents.
Keep your buildings' records this way
Your binder fills itself from what you record, and lists anything still missing.